home *** CD-ROM | disk | FTP | other *** search
- Path: news.gate.net!not-for-mail
- From: dhaire@gate.net (doug haire)
- Newsgroups: comp.dcom.modems
- Subject: Re: Practical Periphs 28.8 Not Connecting to USR Courier
- Date: 7 Feb 1996 22:45:59 -0500
- Organization: CyberGate, Inc.
- Distribution: na
- Message-ID: <4fbrln$1u9m@seminole.gate.net>
- References: <DM9pBE.70u@mccc.edu> <DMFD9F.2IM@mccc.edu>
- NNTP-Posting-Host: seminole.gate.net
- X-Newsreader: TIN [UNIX 1.3 950824BETA PL0]
-
- Pete Holsberg (pjh@mccc.edu) wrote:
- : In article <DM9pBE.70u@mccc.edu>, Pete Holsberg <pjh@mccc.edu> wrote:
- : =We have AT&T DataPorts (14.4) on one hunt group and USR
- : =Couriers on another.
- : =
- : =A user with a PP 28.8 can connect to the DataPorts but not
- : =to the Couriers.
- : =
- : =Can someone suggest a PP initialization string that will
- : =work for both?
- :
- : Here's an update to this most perplexing problem.
- :
- : The user's modem is a Practica; Periph PM288HC II V.34. An
- : ATI command says [43R9] version 1.60. It's initialized to
- : &F1.
- :
- : The other modem is a USR Courier with the latest flash rom
- : code just flashed in. It, too, was initialized with &F1.
- :
- : Calling from the PP to the USR results in lots of noise but
- : no result code from the modem.
- :
- : The PP works fine calling other sites, modems unknown. The
- : USRs work fine with other callers.
- :
-
- Have the PP owner disable V.42 negotiation and see if he can connect then.
- Just a hunch...
-
- --
- "Things are more like they are now than they ever were before."
- [Dwight D. Eisenhower]
-